A facility owner is asked for an ASHRAE Level 2 energy audit, and the quotations arrive with different scopes, different deliverables and different ideas of what Level 2 means. An ASHRAE Level 2 energy audit is an energy survey and analysis that breaks consumption down by system and costs the practical efficiency measures, building on a Level 1 walk-through. The level decides how firm the savings numbers are, because ASHRAE intends Level 1 estimates of savings and cost to be qualitative. This guide explains what Levels 1 to 3 cover, how to choose between them, what an audit includes and where the standard stops. It draws on ASHRAE's published preview of Standard 211-2018, its 2024 addendum and the US Department of Energy's audit-process material. The approach reflects the ASHRAE energy audit support that Global Formulation provides to facility owners.
Audit levels are older than the standard that now defines them. ASHRAE's Procedures for Commercial Building Energy Audits, known as the Green Book, introduced Levels 1, 2 and 3 as shorthand for scoping an audit. It left much room for interpretation. ANSI/ASHRAE/ACCA Standard 211-2018, reaffirmed in 2023, replaces that looseness with defined procedures and minimum reporting, and in the United States it is voluntary unless a jurisdiction makes it mandatory.
ASHRAE's fact sheet on Standards 180 and 211 lists Washington D.C., Washington State, Oregon, Boulder, Atlanta, Philadelphia and Seattle among the jurisdictions that use the standard. Addendum a, approved on 31 October 2024, retitles the standard Standard for Commercial Building Energy Audits and Decarbonization Assessments. It limits decarbonization work to Scope 1 and Scope 2 emissions. This guide covers the energy audit levels only.
Knowing what the standard is only helps once you know what separates the three levels, which is the next question.
The three levels are cumulative. Each successive level builds on the preceding one, so an ASHRAE Level 2 audit, also written ASHRAE Level II, includes everything an ASHRAE Level 1 energy audit requires. What changes at each step is the depth of the survey, the rigour of the calculation and how far the numbers can be trusted for a spending decision. ASHRAE's names for the levels are walk-through analysis, energy survey and analysis, and detailed analysis of capital-intensive modifications.
| Level | What the work involves | What you receive | When to select it |
|---|---|---|---|
| Level 1: walk-through analysis | Utility bill analysis and benchmarking against peer buildings, a brief survey and an initial estimate by hand calculation | No-cost and low-cost measures, capital improvements worth studying and a summary report, with savings and cost that are qualitative | When the savings potential is in doubt, or to screen a portfolio before deeper audits |
| Level 2: energy survey and analysis | A more detailed survey, a breakdown of energy use by system, initial modelling and cost and savings analysis for all practical measures | A costed list of measures with simple payback, operations and maintenance impacts and a list of capital-intensive options | The default level for most buildings, and the usual choice when you want measures to act on |
| Level 3: detailed analysis of capital-intensive modifications | More field data gathering, including sub-metering, detailed modelling and life-cycle cost analysis, with a risk assessment by the auditor | A detailed project cost and savings analysis for each capital measure | For large capital-intensive projects where the decision needs firm numbers |
Simple benchmarking is sometimes called a Level 0 audit, and virtual or remote audits have become common. The standard's authors treat these as initial screening and not as a replacement for an onsite audit by an experienced, qualified energy auditor. The Department of Energy's 2013 audit-process presentation adds that level definitions are not rigid and should capture the objectives of the assessment. Standard 211 later sharpened the boundaries between them.
The right level follows from the decision the audit has to support. A screening question needs a cheaper, shallower answer than a capital replacement does, and paying for depth you will not use wastes budget. Buying too little depth is worse, because a report that cannot carry the decision gets repeated at the next level. The table matches common situations to levels.
| Your situation | Level | Reason |
|---|---|---|
| You doubt that a building or site has worthwhile savings | Level 1 | It identifies no-cost measures and shows whether a deeper audit is justified |
| You manage a portfolio and must rank sites | Level 1, then Level 2 or 3 on the best | The Department of Energy describes Level 1 as a screen for the deeper levels |
| You want a costed list of measures to act on | Level 2 | It costs all practical measures and is the default level for most buildings |
| You are deciding on a large capital replacement, such as chiller or boiler plant | Level 3 | It adds measured data, detailed modelling and life-cycle cost analysis |
| A city or authority requires an audit | The level named in the local rule | The authority having jurisdiction can adjust the standard's scope and reporting |
| You hold only a benchmark or a remote review | Treat as screening | It does not replace an onsite audit by a qualified energy auditor |
A staged approach works: Level 1 to rank, Level 2 to cost the measures, Level 3 only for the capital projects that survive. Each stage reuses the work of the one before, since the levels are cumulative.
Standard 211 is a building standard. It applies to all buildings except single-family houses, multifamily structures of three stories or fewer above grade and manufactured houses. Within a building it lists the systems an audit covers where they exist, and it excludes three end uses. That boundary matters most to industrial owners, because a factory contains loads the standard does not reach.
The systems in scope, as applicable to the building, are:
The standard excludes industrial processes, agricultural processes and irrigation from its end uses.
Within the building scope, process-driven spaces still shape the work. Cleanrooms and laboratories carry ventilation, pressure and cleanliness requirements that every measure must preserve, as our guide to cleanroom and GMP facility design explains. Condenser-water quality affects chiller and cooling-tower performance, which our guide to cooling tower water treatment covers. HVAC upgrades that follow an audit are engineered under our MEP, HVAC and fire protection engineering service. Larger capital measures move into design and delivery, as in our EPC and EPCM project management work.
An audit follows a fixed sequence, and each step depends on the data collected before it. The auditor needs a clean baseline from the utility records, a site visit to see how the systems really run, and a method for costing each measure. The standard sets the minimum content of that work, and the owner decides how much further to go. Seven steps make up the flow for a Level 2 audit.
Simple payback is a first screen, not a verdict. It ignores the life of the equipment and the cost of money, which is why Level 3 adds life-cycle cost analysis for capital decisions.
A disappointing audit has a gap between what was promised and what the owner can use. The gap opens at the baseline, the level, the measure interactions or the verification. Each has a plant consequence that appears after the report is delivered and the money is spent. The table lists the common failures with the step that prevents each.
| What goes wrong | Consequence | How to prevent it |
|---|---|---|
| Utility bills do not match the meters or the records | The baseline is wrong, so every saving is measured from the wrong starting point | Reconcile bills with records, use actual rates instead of blended ones, normalise for weather and explain historical spikes |
| No sub-metering to allocate use | The end-use breakdown rests on estimates | Plan sub-metering early; Level 3 relies on measured field data |
| Level 1 used to support an investment decision | Savings and cost are qualitative, so the capital case rests on soft numbers | Commission Level 2 or Level 3 for any capital decision |
| Measures priced one by one | Interacting measures, such as lighting and cooling load, double count savings | Vet measures for interactive effects before ranking them |
| Predicted savings do not appear after installation | The payback case fails and trust in the audit falls | State the assumptions behind every calculation and agree before installation how savings will be verified from the meters |
| Comfort complaints after a control change | Occupants or processes lose the conditions they need | Keep ventilation, pressure and cleanliness requirements fixed whatever savings are proposed |
| A remote review sold as an audit | No site evidence stands behind the recommendations | Treat it as screening and require an onsite audit for any level |
The Department of Energy's validation checklist covers many of these points: sanity checks, document review, costs with their sources, bills that match records and assumptions that seem reasonable. A buyer can apply the same checks to any report before accepting it.
A well-specified audit request makes quotations comparable and protects the owner from a report that cannot be used. The specification is short, but every line removes a later argument. Work through the items below before inviting quotations. The checklist applies to any level.
On delivery the owner should receive the baseline and benchmark, the end-use breakdown and the ranked measures with cost, savings, simple payback and stated assumptions. The report should also show how interactions were handled, the operations and maintenance impacts and the signed compliance form. At Level 3 it adds the model, the life-cycle cost analysis and the risk assessment. To check the work, pick two measures and re-derive the saving from the stated assumptions, then reconcile the baseline with your own bills.
Owners who want energy audit services scoped to a level and a facility boundary can start from our ASHRAE energy audits service. It covers ASHRAE Level 1, 2 and 3 energy audits, industrial utility audits and savings verification. The checklist above is the brief to bring to that conversation.
An ASHRAE Level 2 energy audit is an energy survey and analysis. It is more detailed than a walk-through, breaks energy use down by system and costs the practical efficiency measures.
It builds on Level 1, so everything a Level 1 audit requires is included. The Department of Energy describes it as the default audit level for most buildings.
Level 1 is a walk-through analysis built on utility bills and a brief survey, and its savings and cost estimates are qualitative. Level 2 adds a detailed survey, an energy breakdown by system and costed practical measures.
Level 3 is a detailed analysis of capital-intensive modifications, with more field data gathering, sub-metering, detailed modelling and life-cycle cost analysis. Each level includes the work of the one before it.
Choose the level from the decision the audit must support. Use Level 1 to screen a building or portfolio. Use Level 2 for a costed list of measures to act on, and Level 3 for a large capital project that needs firm numbers.
If a city or authority requires an audit, use the level named in the local rule, because the authority having jurisdiction can adjust the standard's scope and reporting.
ANSI/ASHRAE/ACCA Standard 211 sets consistent practices for conducting and reporting commercial building energy audits. It defines the procedures for Levels 1, 2 and 3, a common scope of work, the minimum rigour of analysis and minimum reporting requirements.
It applies to all buildings except single-family houses, multifamily structures of three stories or fewer above grade and manufactured houses. Its 2024 addendum a also adds decarbonization assessments for Scope 1 and Scope 2 emissions.
No. Standard 211 excludes industrial processes, agricultural processes and irrigation from the end uses it covers. It applies to buildings and their systems, such as HVAC, lighting, envelope, steam and water systems.
An audit of a manufacturing site that follows the ASHRAE levels therefore needs a stated facility boundary. Agree in writing how process loads are treated, so that quotations can be compared.
Standard 211 defines a qualified energy auditor who certifies compliance. The definition requires experience of commercial building energy audits plus a recognised credential, a professional engineer or contractor status approved by the authority having jurisdiction, or approval by that authority.
Ask any auditor how they meet the definition and any local rule. ASHRAE publishes the standard, but compliance is attested by the auditor on the compliance form.
Compliance with Standard 211 is voluntary until and unless a legal jurisdiction makes it mandatory through legislation. ASHRAE lists several United States jurisdictions that use the standard, including Washington D.C., Washington State, Oregon, Boulder, Atlanta, Philadelphia and Seattle.
Check the local rule for the required level and reporting. Outside the United States, other audit standards and rules apply.
Benchmarking under the standard uses normalised energy consumption spanning at least 12 consecutive months and up to three consecutive years, where available. It compares the building with similar buildings.
Interval data, drawings, equipment lists and operating schedules improve the analysis. Level 3 adds measured field data, including sub-metering for the target systems.
There is no single price, because it depends on the size and complexity of the facility, the number of systems in scope and the distance the auditor must travel. The Department of Energy makes the same point about building complexity, size and travel.
The level matters too, since each level adds survey effort and analysis. Ask for a quotation based on a written scope that states the level, the facility boundary and the deliverables, so that offers can be compared.